Total: 1
Pre-plasma conditions strongly influence laser-plasma interactions in the multi-petawatt (MPW) regime, increasing the need for reliable early-time plasma evolution diagnostics. Among available pre-plasma diagnostics, interferometry remains the most direct method for measuring the spatially resolved electron density of pre-formed plasmas. However, its implementation becomes increasingly challenging at MPW scale dueto steep density gradients, phase-recovery difficulties, strong electromagnetic pulses (EMP), debris accumulation, and high-repetition-rate operation. Compounding these technical challenges, many large-scale facilities lack permanent probe-line architecture and trained diagnostic support, reducing experimental reproducibility and consuming limited beamtime. Future MPW facilities should standardize probe-line architecture, adopt off frequency probing strategies, improve phase-recovery methods for non-symmetric plasmas, integrate emerging real-time analysis capabilities, and engineer diagnostic systems resilient to EMP and high-repetition-rate environments. These advances will enable the user community to reliably characterize pre-plasma formation and laser-plasma dynamics at next-generation MPW facilities.