2607.04026

Total: 1

#1 Production of high-quality plasma discharges via real-time control of plasma current ramp-up using neutral gas injection in Aditya-U tokamak [PDF] [Copy] [Kimi] [REL]

Authors: Suman Dolui, Praveenlal Edappala, Kaushlender Singh, J. Ghosh, R. L. Tanna, A. Kundu, K. A. Jadeja, Ankit Patel, Rohit Kumar, Suman Aich, Harshita Raj, K. M. Patel, M. B. Chowdhuri, P. K. Chattopadhyay, A. Sen, R. Pal

Robust control of plasma current ramp-up is an absolute necessity, as an efficient and uncontaminated plasma current ramp-up is essential for achieving prolonged, high-pressure tokamak plasma discharges. In conventional tokamaks with Ohmic breakdown, the plasma current ramp-up is achieved primarily with pre-fixed temporal profiles of the applied toroidal electric field and the equilibrium magnetic field (Bv). The pre-fixed temporal profiles of these fields are often insufficient to maintain a successful plasma current ramp-up, as several unquantified dynamical variables, such as the condition of the vessel wall and plasma-facing components, influence the plasma current rise. Fuel gas injection in an appropriate quantity at a suitable time during the current ramp-up is therefore used to control the plasma current rise rate, ensuring successful plasma current start-up in Aditya-U. The gas injection time and gas quantity are controlled based on real-time measurement of plasma current rise rate using a digital signal processor (DSP) controller. This special control scheme is capable of achieving the plasma current to rise nearly at the desired rate, resulting in a successful start-up and a stable plasma discharge.

Subject: Plasma Physics

Publish: 2026-07-04 20:50:56 UTC