Medical Physics

2026-03-09 | | Total: 6

#1 Rotation-invariant graph message passing enables acquisition protocol generalisation in learning-based brain microstructure estimation [PDF] [Copy] [Kimi] [REL]

Authors: Leevi Kerkelä, Hui Zhang

Estimating brain microstructure has important applications in medicine and neuroscience. Diffusion-weighted magnetic resonance imaging enables measuring microstructure \textit{in vivo}. Conventional biophysical model fitting can be accurate but is slow and impractical for time-critical clinical use, where machine learning can offer a potential route to rapid estimation. We address the problem of microstructure estimation under arbitrary acquisition protocols where most existing learning-based methods fail due to protocol assumptions, requiring retraining when the protocol changes. We present a graph neural network that represents input data as a point cloud in the 3D space where diffusion-weighted measurements are made and performs rotation-invariant message passing with permutation-invariant pooling, producing fixed-size embeddings that encode microstructure. The inductive biases of our relatively small model were guided by the underlying physics and symmetries of the problem rather than by generic model architectures. Trained on randomised simulated data, our model demonstrates domain generalisation, accurately estimating microstructure from data with unseen real-world protocols without retraining. This approach represents a step towards a "train once, deploy anywhere" architecture, bringing rapid learning-based microstructure mapping closer to clinical deployment.

Subject: Medical Physics

Publish: 2026-03-06 17:29:14 UTC


#2 Sparse probabilistic evaluation for treatment planning: a feasibility study in IMPT head & neck patients [PDF] [Copy] [Kimi] [REL]

Authors: Jenneke I. de Jong, Steven J. M. Habraken, Albin Fredriksson, Johan Sundström, Erik Engwall, Sebastiaan Breedveld, Mischa S. Hoogeman

Probabilistic evaluation improves the trade-off between target coverage and OAR sparing in IMPT but remains computationally demanding. This study proposes sparse probabilistic evaluation (SPE), a computationally efficient approach integrated into a clinical TPS. Clinical plans of 20 IMPT HNC patients treated in 2024 were included. SPE used a predefined setup and range error grid with Monte Carlo computed dose distributions. Two grid settings were evaluated: the maximum error Emax (3$σ$ or 4$σ$) and the number of setup error points nsetup (7, 33, 123). Accuracy and duration of SPE with each grid were evaluated in the calibration group (5 patients). 1000 treatments with normally distributed random ($σ$ = 1 mm) and systematic ($σ$ = 0.92 mm) setup and range ($σ$ = 1.5%) errors were simulated. The dose distribution of the nearest error point in the grid was assigned to each fraction. Probability distributions derived from SPE were compared with those from a reference based on 35,000 Monte Carlo calculations. The found optimal grid (Emax = 3$σ$, nsetup = 33) was applied to the validation group (15 patients). Accuracy of SPE in the calibration group increased significantly as the number of error points increased from 7 (tavg = 2 minutes) to 33 (tavg = 9 minutes), with no further improvement between 33 and 123 (tavg = 27 minutes) error points. Increasing Emax only improved accuracy for values above the 98th percentile. Applying SPE to the validation group resulted in median errors of 0.02 Gy RBE (range:-0.11 to 0.07) for the 10th percentile of the D99.8%, CTV distribution and 0.0 Gy RBE (range:-0.14 to 0.23) for the 95th percentile of the D0.03cc,SpinalCord Core distribution. Sparse probabilistic evaluation achieves sufficient accuracy while requiring clinically acceptable computation times, paving the way for probabilistic evaluation in clinical practice.

Subject: Medical Physics

Publish: 2026-03-06 14:16:38 UTC


#3 CBCT-Based Synthetic CT Generation Using Conditional Flow Matching Model [PDF] [Copy] [Kimi] [REL]

Authors: Junbo Peng, Huiqiao Xie, Tonghe Wang, Xiangyang Tang, Xiaofeng Yang

Daily or weekly cone-beam computed tomography (CBCT) is employed in image-guided radiotherapy (IGRT) for precise patient alignment. However, its clinical utility in quantitative tasks is hindered by severe artifacts and inaccurate Hounsfeld unit (HU). It is essential to enhance CBCT image quality to a level comparable with that of conventional CT scans. This study proposed a conditional flow matching model that gradually transforms a sample from normal distribution to the corresponding CT sample conditioned on the input CBCT image. The proposed model was trained using CBCT and deformed planning CT (dpCT) image pairs in a supervised learning scheme. The feasibility of the conditional flow matching model was verified using studies of brain, head-and-neck (HN), and lung patients. The quantitative performance was evaluated using three metrics, including mean absolute error (MAE), peak signal-to-noise ratio (PSNR), and normalized cross-correlation (NCC). The proposed flow matching model was also compared to other flow matching and diffusion-based generative models for sCT generation. The proposed flow matching model effectively reduced multiple types of artifacts on CBCT images in all the studies. In the study of brain patient, the MAE, PSNR, and NCC of the sCT were improved to 26.02 HU, 32.35 dB, and 0.99, respectively, from 40.63 HU, 27.87 dB, and 0.98 on the CBCT images. In the study of HN patient, the metrics were improved to 33.17 HU, 28.68 dB, 0.98 from 38.99 HU, 27.00 dB, 0.98. In the lung patient study, the metrics were 25.09 HU, 32.81 dB, 0.99 and 32.90 HU, 30.48 dB, 0.98 for sCT and CBCT, respectively. The proposed conditional flow matching model effectively synthesizes high-quality CT-like images from CBCT, achieving accurate HU representation and artifact reduction. This enables more reliable organ segmentation and dose calculation in CBCT-guided online ART workflows.

Subject: Medical Physics

Publish: 2026-03-06 01:04:47 UTC


#4 Ultra-high frequency ultrasound imaging and quantification of microvascular flow in xenograft renal cell carcinoma in an avian chorioallantoic membrane model [PDF] [Copy] [Kimi] [REL]

Authors: Sara Mar, Emmanuel Cherin, Justin Xu, David E. Goertz Hon S. Leong, Christine E. M. Demore

Patient derived xenograft (PDX) tumor models initiated in avian chorioallantoic membranes (CAM) are under investigation to evaluate the effectiveness of therapeutic options with the objective of personalizing treatments. CAM PDXs paired with ultra-high frequency ultrasound (UHFUS) imaging could potentially constitute prospective high throughput assays that can rapidly assess tumor volume and vascular response to therapy. To date, little work has been conducted to adapt and validate UHFUS flow imaging methods to CAM tumor models, which have particular tissue motion challenges that affect microvascular flow detection. Here we report the development and evaluation of an imaging pipeline for UHFUS detection of microvascular flow in a CAM tumor model using interframe subtraction (IS) to suppress tissue clutter. The IS pipeline included a tissue motion compensation (MC) stage prior to clutter filtering and was compared to a singular value decomposition (SVD) clutter filter. The performance was evaluated using UHFUS data acquired in phantom and in vivo Sunitinib-treated renal cell carcinoma. MC substantially reduced tissue motion effects. MC+IS was comparable to MC+SVD filtering at detecting flow within tumors. The results for both IS and SVD filters were dependent on the details of implementation. The UHFUS imaging methods detected a significant decrease in blood flow metrics in treated versus control tumors. An effective imaging pipeline was developed for the assessment of the treatment response of CAM PDX models in a clinically relevant timeframe. The MC+IS approach implemented on B-scan image derived data is less computationally intensive and can be used with widely available UHFUS systems

Subject: Medical Physics

Publish: 2026-03-05 20:19:50 UTC


#5 AI End-to-End Radiation Treatment Planning Under One Second [PDF] [Copy] [Kimi] [REL]

Authors: Simon Arberet, Riqiang Gao, Martin Kraus, Florin C. Ghesu, Wilko Verbakel, Mamadou Diallo, Anthony Magliari, Venkatesan Karuppusamy, Sushil Beriwal, REQUITE Consortium, Ali Kamen, Dorin Comaniciu

Artificial intelligence-based radiation therapy (RT) planning has the potential to reduce planning time and inter-planner variability, improving efficiency and consistency in clinical workflows. Most existing automated approaches rely on multiple dose evaluations and corrections, resulting in plan generation times of several minutes. We introduce AIRT (Artificial Intelligence-based Radiotherapy), an end-to-end deep-learning framework that directly infers deliverable treatment plans from CT images and structure contours. AIRT generates single-arc VMAT prostate plans, from imaging and anatomical inputs to leaf sequencing, in under one second on a single Nvidia A100 GPU. The framework includes a differentiable dose feedback, an adversarial fluence map shaping, and a plan generation augmentation to improve plan quality and robustness. The model was trained on more than 10,000 intact prostate cases. Non-inferiority to RapidPlan Eclipse was demonstrated across target coverage and OAR sparing metrics. Target homogeneity (HI = 0.10 $\pm$ 0.01) and OAR sparing were similar to reference plans when evaluated using AcurosXB. These results represent a significant step toward ultra-fast standardized RT planning and a streamlined clinical workflow.

Subjects: Image and Video Processing , Artificial Intelligence , Machine Learning , Systems and Control , Medical Physics

Publish: 2026-03-06 14:45:44 UTC


#6 Predicting the onset of period-doubling bifurcations via dominant eigenvalue extracted from autocorrelation [PDF] [Copy] [Kimi] [REL]

Authors: Zhiqin Ma, Chunhua Zeng, Ting Gao, Jinqiao Duan

Predicting the occurrence of transitions in the qualitative dynamics of many natural systems is crucial, yet it remains a challenging task. Generic early warning signals like variance and lag-1 autocorrelation identify critical slowing down near tipping points but lack practical thresholds for predicting imminent transitions. More recent studies found that the dynamical eigenvalue is rooted in the framework of empirical dynamical modeling and then estimates the dominant eigenvalue of a system from time series, providing a threshold ($|$DEV$|$ = 1) to predict bifurcations and classify their types. However, its application requires careful calibration of the hyperparameters and focuses on reconstructing system dynamics directly from data. Here, we employ Ornstein-Uhlenbeck process to derive analytic approximations for the lag-$τ$ autocorrelation function prior to period-doubling bifurcation thereby estimating the dominant eigenvalue of dynamical systems, named dominant eigenvalue extracted from autocorrelation (DE-AC), and revealing its dynamic behaviour when approaching a period-doubling bifurcation. Theoretically, dominant eigenvalue tends to $-1$ when the system approaches a period-doubling bifurcation. In particular, we evaluated DE-AC on simulation data from cardiac alternans model and on experimental data from chick heart aggregates undergoing a period-doubling bifurcation. DE-AC reliably detected the beginning of the cardiac arrhythmia (period-doubling bifurcation) in most cases. Moreover, it demonstrated superior sensitivity and specificity as an early warning signal compared to the three widely used indicators -- variance, lag-1 autocorrelation, and dynamical eigenvalue. Our theoretical and empirical results suggest that DE-AC represents a quantitative measure for predicting the onset of potentially dangerous alternating rhythms in the heart.

Subjects: Chaotic Dynamics , Dynamical Systems , Data Analysis, Statistics and Probability , Medical Physics

Publish: 2026-02-22 13:19:13 UTC