#1 A Proton Treatment Planning Method for Combining FLASH and Spatially Fractionated Radiation Therapy to Enhance Normal Tissue Protection [PDF] [Copy] [Kimi] [REL]

Authors: Weijie Zhang, Xue Hong, Ya-Nan Zhu, Yuting Lin, Gregory Gan, Ronald C Chen, Hao Gao

Background: FLASH radiation therapy (FLASH-RT) uses ultra-high dose rates to induce the FLASH effect, enhancing normal tissue sparing. In proton Bragg peak FLASH-RT, this effect is confined to high-dose regions near the target at deep tissue levels. In contrast, Spatially Fractionated Radiation Therapy (SFRT) creates alternating high- and low-dose regions with high peak-to-valley dose ratios (PVDR), sparing tissues at shallow-to-intermediate depths. Purpose: This study investigates a novel proton modality (SFRT-FLASH) that synergizes FLASH-RT and SFRT to enhance normal tissue protection across all depths. Methods: Two SFRT techniques are integrated with FLASH-RT: proton GRID therapy (pGRID) with conventional beam sizes and proton minibeam radiation therapy (pMBRT) with submillimeter beams. These are implemented as pGRID-FLASH (SB-FLASH) and minibeam-FLASH (MB-FLASH), respectively. The pGRID technique uses a scissor-beam (SB) method to achieve uniform target coverage. To meet FLASH dose (5 Gy) and dose-rate (40 Gy/s) thresholds, a single-field uniform-dose-per-fraction strategy is used. Dose and dose-rate constraints are jointly optimized, including a CTV1cm structure (a 1 cm ring around the CTV) for each field. Results: Across four clinical cases, MB-FLASH and SB-FLASH plans were benchmarked against conventional (CONV), FLASH-RT (FLASH), pMBRT (MB), and pGRID (SB) plans. SFRT-FLASH achieved high FLASH effect coverage (~60-80% in CTV1cm) while preserving PVDR (~2.5-7) at shallow-to-intermediate depths. Conclusions: We present a proton treatment planning approach that combines the FLASH effect at depth with high PVDR near the surface, enhancing normal tissue protection and advancing proton therapy.

Subject: Medical Physics

Publish: 2025-05-09 17:57:30 UTC


#2 Towards order of magnitude X-ray dose reduction in breast cancer imaging using phase contrast and deep denoising [PDF] [Copy] [Kimi] [REL]

Authors: Ashkan Pakzad, Robert Turnbull, Simon J. Mutch, Thomas A. Leatham, Darren Lockie, Jane Fox, Beena Kumar, Daniel Häsermann, Christopher J. Hall, Anton Maksimenko, Benedicta D. Arhatari, Yakov I. Nesterets, Amir Entezam, Seyedamir T. Taba, Patrick C. Brennan, Timur E. Gureyev, Harry M. Quiney

Breast cancer is the most frequently diagnosed human cancer in the United States at present. Early detection is crucial for its successful treatment. X-ray mammography and digital breast tomosynthesis are currently the main methods for breast cancer screening. However, both have known limitations in terms of their sensitivity and specificity to breast cancers, while also frequently causing patient discomfort due to the requirement for breast compression. Breast computed tomography is a promising alternative, however, to obtain high-quality images, the X-ray dose needs to be sufficiently high. As the breast is highly radiosensitive, dose reduction is particularly important. Phase-contrast computed tomography (PCT) has been shown to produce higher-quality images at lower doses and has no need for breast compression. It is demonstrated in the present study that, when imaging full fresh mastectomy samples with PCT, deep learning-based image denoising can further reduce the radiation dose by a factor of 16 or more, without any loss of image quality. The image quality has been assessed both in terms of objective metrics, such as spatial resolution and contrast-to-noise ratio, as well as in an observer study by experienced medical imaging specialists and radiologists. This work was carried out in preparation for live patient PCT breast cancer imaging, initially at specialized synchrotron facilities.

Subjects: Medical Physics , Computer Vision and Pattern Recognition

Publish: 2025-05-09 06:15:28 UTC


#3 UltraGauss: Ultrafast Gaussian Reconstruction of 3D Ultrasound Volumes [PDF1] [Copy] [Kimi] [REL]

Authors: Mark C. Eid, Ana I. L. Namburete, João F. Henriques

Ultrasound imaging is widely used due to its safety, affordability, and real-time capabilities, but its 2D interpretation is highly operator-dependent, leading to variability and increased cognitive demand. 2D-to-3D reconstruction mitigates these challenges by providing standardized volumetric views, yet existing methods are often computationally expensive, memory-intensive, or incompatible with ultrasound physics. We introduce UltraGauss: the first ultrasound-specific Gaussian Splatting framework, extending view synthesis techniques to ultrasound wave propagation. Unlike conventional perspective-based splatting, UltraGauss models probe-plane intersections in 3D, aligning with acoustic image formation. We derive an efficient rasterization boundary formulation for GPU parallelization and introduce a numerically stable covariance parametrization, improving computational efficiency and reconstruction accuracy. On real clinical ultrasound data, UltraGauss achieves state-of-the-art reconstructions in 5 minutes, and reaching 0.99 SSIM within 20 minutes on a single GPU. A survey of expert clinicians confirms UltraGauss' reconstructions are the most realistic among competing methods. Our CUDA implementation will be released upon publication.

Subjects: Image and Video Processing , Computer Vision and Pattern Recognition , Medical Physics

Publish: 2025-05-08 20:53:47 UTC