Total: 1
According to commonly consented theories, the minimum hardware requirement for gaze tracker is one camera and two light sources to realize gaze estimation with free head movements. However, in some scenarios such as eye tracking on mobile devices, it is preferable to use less components, especially light sources. We propose a gaze estimation method with one camera and one light source. A "virtual light source" is introduced, which is geometrically placed symmetrically to the real light source with respect to the camera, and generates a "virtual glint" in the acquired image. We estimate the "virtual glint" by exploiting the relationship between the distance between two pupils and two glints in the captured image, and estimate the gaze with polynomial regression assuming two light sources are available. A new normalization factor for regression method is verified, which turns out to be practical for one-glint system. The performance is proved to be acceptable, while degradation is noticed compared to system with two actual light sources.