In preparation for HL-LHC operation, a number of new detector systems are being constructed with timing precision on physics objects of 50 picoseconds. These time stamps will reduce the level of pileup induced backgrounds as the number of interactions per crossing will reach of order 100-200. In this report we note that this high pileup level will necessitate a new approach to calibration of these large timing arrays (typically with several ×105 channels) since a single t0 reference is hard to come by in regular data taking. We demonstrate that enhancing the usual pair of timing ASIC data (ie threshold time and amplitude or time-over-threshold) with a 2nd threshold time greatly simplifies the analysis of amplitude walk. Since slope at threshold is directly relevant for amplitude walk, day-1 walk calibration can often have an analytical solution.

Subjects: Instrumentation and Detectors , High Energy Physics - Experiment , Nuclear Experiment

Publish: 2025-07-08 19:25:02 UTC