Silicon sensors are the foundational detection medium for X-rays and charged particles. While their bulk dopant distribution determines device performance, it is conventionally assumed homogeneous because traditional profiling is destructive, spatially restricted, and insensitive at the relevant concentrations. Here we introduce a non-destructive 3D doping imaging technique that turns the readout electronics of a charge-integrating hybrid pixel detector into a massively parallelized capacitance-voltage profiler. With a few tens of micrometres of 3D resolution over wafer-scale areas at concentrations on the order of $10^{11}$ cm$^{-3}$, we image the bulk doping concentration of operational sensors. Macroscopically, we resolve depth-evolving concentric doping rings; microscopically, we uncover scattered doping anomalies that distort local electric fields. The rings modulate the depletion voltage, while the anomalies disrupt local charge collection, a previously overlooked cause of pixel yield and performance degradation. By bridging manufacturing signatures with microscopic defects, this approach provides a non-destructive framework for sensor characterization and yield optimization.
Low Gain Avalanche Detectors (LGADs) achieve time resolutions below 50 ps through internal charge multiplication, yet the gain is not a fixed device property as the space-charge of the multiplied electron-hole density screens the gain layer field, which suppresses further impact ionization. While TCAD simulations reproduce the average gain suppression, their deterministic treatment of a continuous charge density cannot capture the event-by-event fluctuations that determine the timing performance. We present a Monte Carlo study of space-charge-induced gain suppression in LGADs using the Garfield++ framework, in which the dynamic field of the drifting carriers, computed from a coarse-grained system of charged rings, is superimposed on TCAD-computed static field maps of Centro Nacional de Microelectrónica (CNM) and Hamamatsu Photonics (HPK) produced sensors while preserving single carrier avalanche statistics. The simulated gain reproduces published two-photon absorption-transient current technique measurements across two orders of magnitude in injected charge, including the dependence on the injection depth. For minimum ionizing particles, the event-by-event coupling between deposited charge and gain compresses the Landau tail of the multiplied charge, narrowing the signal arrival time distribution and improving the intrinsic time resolution of the HPK-S1 sensor investigated in this work from 53.9 $\pm$ 1.0 ps to 44.5 $\pm$ 0.9 ps. Treating the primary ionization as a stochastic sequence of charge clusters, it is further shown analytically that any gain suppression that decreases with the cluster size narrows the centroid time distribution.
Classical crystallography determines orientation and unit-cell geometry from a rotation series collected from a single specimen, whereas serial crystallography acquires one still exposure from each of many randomly oriented microcrystals and must reconstruct a complete dataset by pooling partial measurements across the ensemble. In serial experiments, each frame typically contains only a subset of reflections, and frames with few reliable peaks (the small-N regime) are especially difficult to index blindly, because multiple incorrect lattices or orientations can explain sparse observations. The approach implemented in GLINT addresses this small-N regime by treating the dataset, rather than the individual frame, as the unit of inference. Candidate solutions are generated for many frames, weak but recurrent lattice hypotheses are pooled across the ensemble to identify a shared unit cell, and each frame is then registered against that consensus cell through a known-cell orientation search with lower dimensionality than blind indexing. In benchmark tests, GLINT matched the strongest blind indexer in the comparison on indexing yield at roughly 40x lower per-frame blind-indexing latency against XGANDALF's fastest configuration, and batched known-cell registration ran entirely on one GPU, allowing cell discovery on the fly during serial data collection. On experimental serial data, frames indexed blind by GLINT merged to crystallographic quality (CC* = 0.90), while the method rejected non-crystal images rather than forcing unsupported indexing assignments. These results demonstrate that indexing performance can be evaluated not only by indexing yield and throughput, but also by the quality of the resulting merged crystallographic data.
Organic liquid scintillators are used since several decades, especially in neutrino physics. They excel at the detection of low-energy particles where energy and timing information is required. Organic liquid scintillators have advantages such as high light yield, radio purity, cost effectiveness, and more. However, they also exhibit disadvantages, most prominently a lack of vertex resolution and particle identification. Various novel ideas have emerged over the course of the last decade to improve the performance of organic liquid scintillators. Among them are most prominently hybrid and opaque scintillators. In this proceedings, these novel scintillators are reviewed and their current applications in the research fields of neutrino and dark matter physics are illustrated.
We explore aspects of an unorthodox ton-scale xenon gas time projection chamber detector operated at normal temperature and pressure (NTP), designed for $0νββ$ discovery at $\sim10^{27}$ year sensitivity. At fixed active mass, a greater transparency to $γ$-ray backgrounds and better track clarity exists at NTP relative to higher density. Operation at NTP also alleviates difficulties with pressure containment and significantly reduces HV requirements. With metre-scale electron tracks at a few MeV, event topology can be used to efficiently reject the copious $γ$-ray backgrounds by factors ranging from 550--1200, largely compensating for the greater surface area of the detector. Event topology is captured from anode plane signals combined with sensing the secondary ion component arriving at the cathode plane. A molecular gas additive limits diffusion of the secondary electron tracks to below a cm and provides stable proportional avalanche gain. An energy resolution $δ$E/E $\leq$ 1\% FWHM seems possible. A 100 kg scale demonstrator for this detector technology could lead directly to a ton-scale search.
The Cr$_2$O$_3$ solid target for low-energy $^{16}$O+$^{16}$O fusion experiments was fabricated using filtered cathodic vacuum arc (FCVA) deposition. Its composition, oxygen areal density and impurity content were characterized by elastic backscattering spectrometry (EBS), and the impurity-induced background contributions were investigated by in-beam $γ$-ray spectroscopy. EBS results indicate that the Cr$_2$O$_3$ film exhibits good stoichiometry and uniformity, with $^{16}$O areal densities ranging from $(3.24-3.25)\times10^{17}$ atoms/cm$^2$. The EBS analysis reveals a carbon atomic fraction of approximately 1.25-1.29\% in the Cr$_2$O$_3$ layer, while a large amount of carbon impurities are also identified on the surface of Cr substrate. In-beam $γ$-ray spectra reveal prominent transitions associated with $^{27}$Al and $^{24}$Mg at 844, 1015, and 1369 keV, mainly originating from $^{12}$C+$^{16}$O fusion reactions induced by carbon impurities under $^{16}$O irradiation. Meanwhile, characteristic $γ$-rays emissions from evaporation channels of the $^{16}$O+$^{16}$O reaction, including $^{31}$S, $^{31}$P, and $^{28}$Si, were also observed and can be used to extract the $^{16}$O+$^{16}$O fusion cross sections. This work provides an experimental basis for the development of high-purity oxide targets and the optimization of target configurations for future low-background $^{16}$O+$^{16}$O fusion cross section measurements.
AC-coupled Low Gain Avalanche Diode (AC-LGAD), evolved from the standard LGAD technology, are silicon detectors characterized by exceptional temporal and spatial resolutions. This work proposes a novel sensor named AC-coupled Cross Strip LGAD (CS-LGAD) structure with dual-layered overlapping strip electrodes. It can achieve two-dimensional particle position measurement with low readout density while also inheriting the high temporal resolution of the LGAD. The sensor structure, doping and current-voltage (I-V) characteristics of the sensor were investigated through TCAD simulations. Additionally, Monte Carlo simulations were employed to simulate the signal response of CS-LGAD to minimum ionizing particles (MIPs). The response of MIPs hitting different positions was simulated, and the reconstruction of particle coordinates (x and y) was achieved based on the sharing of charges on the dual-layer electrodes. The spatial resolution might reach 3.6% and 5.5% of the pitch size in the x and y directions, respectively, according to the simulation. The proposed CS-LGAD is a promising 4D detector with low mass and low readout density.
The Fast Interaction Trigger detector of the ALICE apparatus at the LHC includes a Cherenkov subsystem utilizing 52 Planacon XP85002/FIT-Q microchannel plate-based photomultiplier tubes. It is a precise trigger, multiplicity and luminosity detector located in the forward region, where the flux of collision products is the largest. The photon load reaches up to 2*10^8 photoelectrons / cm^2 / s for the innermost photosensors, corresponding to 0.4 μA / cm^2 average anode current density. The lifetime-extended version of the Planacon MCP-PMT with atomic layer deposition cannot handle such a large anode current. We therefore use the non-ALD version of the Planacons that, on the other hand, suffer from a limited lifetime in terms of the integrated anode charge. Here we present the long-term performance trends of the non-ALD Planacons up to the integrated anode charge of 2 C / cm^2. We demonstrate that the low-gain operation strategy allows to maintain excellent time resolution in multiphoton mode unchanged up to that large integrated charge. While the majority of the equally illuminated MCP-PMTs feature almost identical ageing speed, two outliers suffering from a faster ageing coincide with the outliers in the noise characteristics measured prior to the irradiation. Moreover, we report that the effective ageing speed is partially suppressed by the self-recovery of the response of aged MCP-PMTs newly observed by our group during months-long no-beam periods.
We present the design and performance of an optical cryostat for testing silicon photomultipliers (SiPMs) with vacuum-ultraviolet (VUV) light. The cryostat operates within a temperature range of 120 to 340 K, achieving a temperature stability of 1.2 mK, measured in a rolling 10-minute window once settled within a liquid nitrogen fill-cycle, and 13.8 mK over a complete fill-cycle including the refill transient. The cryostat includes a VUV-transparent CaF$_2$ viewport with a 142 mm diameter clear aperture, which limits the optically accessible sample area to 158 cm$^2$. The viewport is integrated into a sealed dark box and optical table to facilitate light delivery. VUV illumination is achieved using a custom xenon scintillation lamp or a xenon flash lamp, with a motorized two-axis linear rail system ensuring precise light positioning over the sample. This paper details the cryostat and optical system design, as well as commissioning current-voltage (IV) measurements using Hamamatsu VUV-sensitive SiPMs from 165 to 295 K and a measurement of the photodetection efficiency at 165 K.
This paper reports on the commissioning of the DarkLight experiment at the ARIEL superconducting electron linear accelerator located at TRIUMF in Vancouver, Canada. DarkLight was designed to utilize the ARIEL electron beam to search for a new boson, $A^\prime$, which preferentially couples to leptons, with a mass in the range 13-17 MeV/$c^2$. Such a boson could be produced via the $e^-~X\rightarrow e^-~X~A^\prime$ process, and the resulting $A^\prime\rightarrow e^+~e^-$ decay used to reconstruct the invariant mass of the $A^\prime$. The $e^+e^-$ pair is detected using a pair of magnetic spectrometers. Each spectrometer is instrumented with two triple GEM detectors and a scintillating strip hodoscope to trigger the event readout. Electron beam energies between 10 and 30 MeV were used to commission the experiment with a 1$~μ$m thick carbon target. With both spectrometer polarities set to select electrons, elastic and Møller scattering were used to examine detector performance and compare with predicted distributions from Monte Carlo simulations. Planned upgrades to the e-linac will allow searches to be made with beam energies up to 50 MeV using a 1$~μ$m thick tantalum target.
Nuclear magnetic resonance (NMR) spectroscopy is a powerful probe of molecular structure and dynamics but typically requires large spin ensembles. Here, we demonstrate nanoscale NMR detection of fluorinated DNA using individual near-surface nitrogen-vacancy (NV) centers in diamond nanopillar waveguides under ambient conditions. We covalently tether $^{19}$F-labeled oligonucleotides to mixed nitrogen- and oxygen-terminated surfaces, localizing target spins within the nanoscale sensing volume. Probabilistic spin simulations suggest that the measured signals are consistent with those expected from a few molecules and depend strongly on NV-molecule separation, configuration, and local surface heterogeneity. These results establish a framework for NMR of surface-tethered biomolecules and identify key challenges for single-molecule structural elucidation.
Direction-dependent instrumental polarisation is a major systematic limitation in high-fidelity single-dish radio polarimetry, yet a unified characterisation of beam leakage and the conditioning of polarisation recovery is lacking for the Ghana Radio Astronomy Observatory (GRAO) 32-m telescope. We aim to establish a quantitative, direction-dependent polarimetric beam model at 5.0 and 6.7 GHz. High-resolution \texttt{GRASP} electromagnetic simulations of the nominal telescope configuration are used to derive the full complex Jones response and corresponding Mueller matrices, from which beam shape, beam squint, instrumental Stokes leakage, and intrinsic cross-polarisation ratio (IXR) are evaluated across the primary beam. The Stokes $I$ beams have half-power beam widths of $396.4$ and $295.3$ arcsec at 5.0 and 6.7 GHz, respectively, with main-beam efficiencies of $56.4$ and $55.6$ per cent. At 5.0 GHz, the circular-polarisation beam squint is $9.96$ arcsec ($2.5$ per cent of the HPBW), whereas no statistically significant squint is detected at 6.7 GHz. Leakage from Stokes $I$ into linear polarisation remains below $0.1$ per cent within the half-power beam but increases substantially towards the sidelobes. IXR reaches approximately $80$ dB on axis and decreases with angular offset. These results establish the intrinsic electromagnetic polarimetric response of the GRAO 32-m telescope and provide a quantitative baseline for direction-dependent calibration and subsequent observational validation.
A dedicated data acquisition (DAQ) system has been developed for the SUB-Millicharge ExperimenT (SUBMET) at the Japan Proton Accelerator Research Complex (J-PARC), a search for particles carrying a fractional electric charge $Q = εe$ with $ε$ below $\mathcal{O}(10^{-3})$, hereafter referred to as millicharged particles (mCPs). Because such particles are expected to produce at most a few scintillation photons, the system is optimized for single-photoelectron detection from the photomultiplier tubes (PMTs), combining high-speed waveform digitization with precise timing. To capture eight consecutive proton bunches of the 30 GeV J-PARC beam within a single trigger, the eight channels of the Domino Ring Sampler 4 (DRS4) chip are cascaded in groups of four to form two readout inputs, each sampling 4096 points continuously at 820.5 MHz over an effective time window of 5 us. After calibration, timing differences between channels are within 1 ns on the same DRS4 chip, 2 ns on the same board, and 8 ns across different boards, well within the 30 ns coincidence window of the experiment. The front-end electronics achieve an RMS noise below 0.4 mV. The baseline is deliberately offset upward such that the negative-going pulses span a larger fraction of the digitizer range, improving voltage resolution and dynamic range. A trigger control board aggregates data from multiple readout boards and sustains the data-transfer rate required for beam operation. The measured performance confirms that the DAQ system meets the timing, noise, and throughput requirements of the experiment.
We report the results of an experimental search for ultralight axion-like dark matter in the mass ranges 19.5--20.5 and 21.5--22 neV. The Cosmic Axion Spin Precession Experiment-electric probes the axion-nuclear electric dipole moment coupling. We perform solid-state nuclear magnetic resonance on $^{207}$Pb spin ensembles which reside in a polarized ferroelectric crystal. The background axion-like dark matter field induces an oscillating torque on the $^{207}$Pb spins via the electric dipole moment coupling $g_{d}$. The experiment is calibrated with pulsed magnetic resonance measurements covering two frequency bands (4.6--5.0 and 5.2--5.3 MHz) that correspond to the axion Compton frequencies associated with the identified axion mass ranges. By sweeping the leading magnetic field applied to the sample, we are able to detect the $^{207}$Pb nuclear magnetic resonance in these frequency ranges using a superconducting quantum interference device, inductively coupled to the sample with a broadband circuit. We establish the upper bounds $|g_{d}| < 4\times 10^{-4}$ GeV$^{-2}$ with 95% confidence in these frequency bands. Our results demonstrate the detection and small-tip angle calibration of low-field $^{207}$Pb nuclear magnetic resonance, allowing for sensitivity to axion-like dark matter in the nanoelectron-volt axion mass range.
Rare-event search experiments continue to extend their sensitivities to unprecedented levels. This requires increasingly small backgrounds, and shielding schemes that can suppress external backgrounds by several orders of magnitude. Moreover, detailed simulations are required to attain a good understanding of these experimental backgrounds. Studies have suggested, however, that simulations and computing-related tasks contribute approximately 10\% to the average particle physicist's carbon footprint. With backgrounds frequently below 0.01 counts per kg of target per keV of energy, simulations require more computing resources; growing a rare-event researcher's computing-related carbon footprint. Event biasing is often applied in shielding simulations as a remedy, yet there is a lack of systematic guidance on how to maximally benefit from them. An optimisation study for the importance-splitting biasing technique is discussed, focused on balancing statistical precision with simulation CPU-time, and how this can benefit the average researcher's carbon footprint.
In the Shenzhen Superconducting Soft X-ray Free Electron Laser (S3FEL), Continuous Wave (CW) Low-Level Radio Frequency (LLRF) systems perform critical functions including adjusting the power coupling of accelerator cavities, regulating the amplitude and phase of the RF field, and maintaining the resonance frequency and phase of the cavities. These functions are essential to ensure the electron beam operates at the accelerating phase. Within S3FEL, each superconducting cavity is driven by a solid-state amplifier (SSA), with each SSA paired with a dedicated LLRF system. Based on the distinct acceleration cavities employed, the CW LLRF systems for S3FEL are categorized into four types: 1. Primary accelerator LLRF systems (superconducting, 1.3 GHz; quantity: 168), 2. Harmonic cavity LLRF systems (superconducting, 3.9 GHz; quantity: 16), 3. VHF electron gun LLRF systems (room temperature, 216 MHz; quantity: 4), 4. Buncher LLRF systems (room temperature, 1.3 GHz; quantity: 2). These four LLRF system categories exhibit differing requirements for RF field and acceleration cavity control. This report presents the preliminary design schemes for these four types of CW LLRF systems.
Gravitational force is proportional to the mass of an attracting body; therefore, changes in subsurface mass can be detected using gravimetry. In the near subsurface, mass variations are primarily driven by changes in water storage, meaning that gravity measurements provide direct information on variations in water mass. Traditionally, groundwater and soil water dynamics are monitored using point-scale instruments that require direct installation into the subsurface. In contrast, gravimetry is a non-invasive method that integrates signals over a larger spatial extent. Recent advancements in gravimeter technology have significantly improved measurement accuracy and long-term stability under field conditions, thereby expanding their potential for hydrological applications. This review summarizes recent developments in gravimetric instrumentation and provides essential background on gravimeters used for ground-based measurements and their application in hydrology, aiming to facilitate their broader use. In addition, it presents an overview of studies in hydrology and hydrogeology that have successfully applied gravimetry to quantify subsurface water storage changes, estimate hydrological parameters, and constrain numerical models. A perspective on future advancement in gravimetry and resulting potential applications is given.
Fast and nonuniform translocation through solid-state nanopores limits both the detection of small molecular labels and their precise localization along molecular carriers. In this work we report the detection and localization performance of nucleotide-based molecular labels along double-stranded DNA scaffolds using solid-state nanopores in thin planar membranes. For small labels that are challenging to resolve individually, we introduce an anchoring strategy where readily detectable bulky labels serve as reference points to align multiple translocation events, enabling population-based detection and localization of smaller molecular features. The measured anchor positions constrain a probabilistic model of translocation velocity, identifying the most probable velocity profile for each event and enabling nonlinear trace "unwarping" for improved multi-event alignment. A complementary window-based evidence aggregation procedure accumulates weak but consistent label signatures across events, enabling detection of features that are individually masked by noise. These approaches enable robust recovery of single-dumbbell labels (DB1) on the order of 28 nucleotides and reduce mean localization errors to as low as 10 base pairs for DB3 labels and 40 base pairs for DB1 labels when averaging over multiple events. Stronger fractional DNA-associated current blockades, used as proxy for smaller pore geometries, are additionally associated with improved detection and lower localization error across membrane-based nanopore fabrication techniques. Overall, anchor-guided alignment provides a route to higher-density molecular information readout without compromising throughput via controlled translocation approaches.