2026-07-10 | | Total: 3
A neutron-sensitive sampling calorimeter based on alternating lead absorber and gadolinium-loaded liquid scintillator layers is investigated using detailed Geant4 Monte Carlo simulations. In addition to the conventional prompt calorimetric signal, the proposed detector records delayed energy from neutron moderation and capture, providing direct information on the neutron component of hadronic showers. A six-layer Pb/LAB-Gd calorimeter exposed to 10~GeV protons is studied to characterize its neutron response and evaluate its impact on calorimetric performance. The delayed deposited energy is found to be almost perfectly proportional to the neutron-capture multiplicity, providing a direct calibration of the neutron-sensitive signal. Event-by-event analyses further reveal a clear relationship between the prompt calorimetric response and the delayed neutron observable, demonstrating that the latter contains substantial information on the invisible hadronic energy. Exploiting this correlation through a simple nonlinear event-by-event correction improves the prompt-energy resolution from 21.8% to 13.3% without rejecting events. Furthermore, the analysis of events with similar neutron multiplicities indicates that neutron-production fluctuations constitute a major contribution to the overall hadronic energy resolution. These results demonstrate the potential of gadolinium-loaded sampling calorimeters to recover part of the invisible hadronic energy and significantly improve hadronic energy reconstruction and energy resolution.
We present the development of a silicon-based ultra-fast X-ray beam size monitor (SiXRM) for SuperKEKB. The system enables, for the first time at SuperKEKB, bunch-by-bunch measurements of the vertical beam size using synchrotron radiation. The detector combines a silicon strip sensor board, amplifier boards, and fast waveform readout electronics. Beam measurements demonstrate clear reconstruction of the bunch structure and X-ray images for individual bunches. The measured beam sizes show good agreement with those obtained from the existing CMOS-based XRM system. The measurement precision is estimated to be better than 6.4 $μ$m. This system provides a powerful tool for studying beam dynamics and optimizing luminosity in high-luminosity colliders.
We use whispering-gallery-mode analysis to characterise the microwave dielectric properties of single-crystal TeO$_2$ at cryogenic temperatures and compare its loss performance with other low-loss dielectric materials. Finite-element modelling is combined with measurements at room temperature, 4 K, and 20 mK to develop accurate cryogenic simulations and extract the anisotropic dielectric permittivities, giving $\varepsilon_\parallel=25.75\pm0.08$ and $\varepsilon_\perp=20.90\pm0.07$. Loss measurements reveal quality factors as high as $9\times10^6$ and minimum loss tangents approaching $3\times10^{-8}$, placing TeO$_2$ among promising low-loss dielectrics for cryogenic microwave applications. Electron-spin-resonance spectroscopy further indicates a clean spin environment, while identifying distinct spin systems consistent with the known properties of the crystal.