2026-06-19 | | Total: 5
Cosmic-ray muon tomography records only a few detector-plane crossings per particle, while material information enters through stochastic scattering and energy loss along the path. Most pipelines first compress these hits to a per-muon scattering summary and assign a nominal momentum, moving the inverse problem away from the raw measurements. We introduce Raw-Hit Muon Tomography (RHMT), a measurement-domain formulation built directly on detector hits. RHMT-S projects out the unknown straight track and evaluates the remaining hit contrast with a Fermi--Eyges covariance; marginalizing the unknown scattering scale gives a blank-calibrated Student-$t$-type likelihood. RHMT-E fits the hits in a six-plane magnetic spectrometer to estimate each muon's log momentum loss and models it as a Bethe--Bloch line integral of the electron-density-related contrast $ρZ/A$. In a controlled Geant4 benchmark, RHMT-S improves the mean ROC-AUC over four-plane scattering baselines ($0.84$--$0.86$ versus $0.81$ for ASR), and RHMT-E provides a separate energy-loss contrast for aluminium, where scattering contrast is weak.
We present a study of charge sharing and electronic cross-talk in second-generation Large-Area Picosecond Photodetectors (LAPPD Gen 2). The LAPPD is a vacuum-based device consisting of a photocathode, two microchannel plates, and a resistive anode that capacitively couples to an 8 $\times$ 8 pixelated readout board (25.4 mm $\times$ 25.4 mm pixel area). Using a picosecond pulsed laser, we measure signal distributions across the resistive anode and quantify coupling between target and neighboring pixels. We further examine the relationship between dark-count rate and LAPPD voltage settings, identifying decay behavior characterized by fast, intermediate, and slow relaxation timescales. We additionally observe the LAPPD behaving as a resonant cavity by injecting electrical pulses into the readout board. To further interpret observed signals, we develop a pulse-classification method and identify additional features at approximately 60 ns and 110 ns. Finally, we implement a first-principles Monte Carlo simulation to model the radial and temporal distributions of observed signals, including contributions from electron backscatter and potential ion afterpulsing. The simulation shows reasonable agreement with the experimentally derived pulse classifications.
Extending earlier work in Physics-informed Meta-instrument for eXperiments (PiMiX) [1], PiMiX~2.0 is an artificial-intelligence (AI)-enhanced data-fusion and analysis framework that integrates multi-experiment multi-modal radiographic imaging and tomography (RadIT) with physics-informed reasoning and agentic AI workflows. The framework supports automated data ingestion, multimodal image processing from one or more experiments, three-dimensional (3D) and time-resolved three-dimensional (4D) reconstruction, and physics-aware interpretation of experimental observations. The PiMiX agents are designed for deployment on desktop and laptop systems commonly used in experimental workflows, while remaining scalable to high-performance computing environments for computationally intensive tasks. By coupling RadIT instrumentation and measurements with geometry, physics, computation, and statistical inference, PiMiX 2.0 aims to accelerate RadIT data processing, knowledge extraction, improve reproducibility, and enable more integrated analysis and workflows in high-temperature plasmas, nuclear fusion, advanced manufacturing, other static and dynamic experiments.
The J-PARC E16 experiment aims to search for signatures of chiral symmetry restoration. It studies in-medium modifications of vector mesons that decay via the dielectron channel. The measurements use a high-intensity 30 GeV proton beam with C and Cu targets at rates up to 10 MHz. To achieve this, the experiment upgrades its tracking, by introducing innermost detector modules constructed with the same technology and procedures as the modules of the Silicon Tracking System (STS) of the Compressed Baryonic Matter (CBM) experiment at Facility for Antiproton and Ion Research (FAIR). A total of 15 modules were assembled, tested, characterized and then installed in the E16 detector setup. The detector was commissioned in a beam test experiment at Tsukuba, where the detector modules could be exposed to a 3 GeV electron beam. In preparation for the beam test the modules were characterized and calibrated, and performance studies were accomplished to assess the quality of the setup. During beamtime, three modules were operated and illuminated in two planes by the electron beam. This paper presents the results of the construction, characterization, commissioning, and operation of the E16-STS modules in beam test experiments.
Squeezed vacuum lets gravitational-wave detectors and other quantum sensors surpass the standard quantum limit, and is optimal in the loss-limited regime; phase noise breaks this optimality. Numerically optimizing the quantum Fisher information across the loss and phase-noise landscape, we identify non-Gaussian states that outperform any Gaussian state. These fall into three classes: Fock-like, cubic-phase-like, and states with discrete rotational symmetry. Limiting the average number of photons in the input state to $\bar{n}=5$, with $1-η= 5\%$ photon loss and 200 mrad phase noise, the non-Gaussian advantage reaches up to 2.2 dB. Furthermore, we observe that the non-Gaussian advantage can persist even when the measurement strategy is homodyne detection.