Strip scintillator detectors are used nowadays in many fields of applied physics, particularly in medicine, civil engineering, mapping of underground resources, and security. In this work we provide an analytical description of light transport in a cuboid-shaped strip scintillator detector from the scintillation location to the detecting surface. We use kaleidoscopic-ray-tracing approach to reproduce the average time profile of the energy deposition (light collection) in the detecting surface. We demonstrate the applicability of the model on the case of PWO crystal of $1.5\times 1.5 \times 30$ cm$^3$ size. We show that the results achieved in the model are in good agreement with Monte Carlo (MC) simulation. Notably, the developed model requires dozens of milliseconds to be implemented, thus, it is applicable for real-time calibration of the detector, while the MC simulation takes hours. Also, we highlight that the kaleidoscopic-ray-tracing itself being used in MC simulations can highly speed them up in the case of specular reflectors.
Silicon strip detectors for the ATLAS Inner Tracker (ITk) at the HL-LHC must withstand harsh radiation conditions, including fluences of up to 1.6E15 1 MeV n$_{eq}$/cm$^{2}$ and total ionizing doses (TID) of up to 66 Mrad. These requirements are met using radiation-hard n+-in-p technology implemented in the ATLAS18 silicon strip sensors currently under production. This work presents a combined study of gamma-irradiation effects in ATLAS18 silicon sensors, including both segmented miniature strip sensors (minis) and unsegmented MD8 diodes fabricated on ATLAS18 production wafers. The samples were irradiated with a $^{60}$Co gamma source to multiple low TIDs between 0.5 and 100 krad, corresponding to the dose range relevant for the early operational phase of the ITk tracker. Additional measurements extending up to a few Mrad were performed to investigate the saturation of surface related damage effects. Post-irradiation characterization included measurements of total, bulk, and surface leakage currents, as well as capacitance-voltage measurements used to extract the full depletion voltage. The thermal stability of radiation-induced defects was studied using isochronal annealing between 80°C and 300°C and isothermal annealing at 60°C and 160°C. In addition, complementary studies of MD8 diodes irradiated to ultra-high doses of several hundred Mrad, well beyond the ATLAS ITk requirements, are included to investigate possible bulk-related effects induced by pure gamma irradiation and their annealing behavior. The combined analysis of low- and ultra-high-dose irradiation provides a comprehensive picture of surface- and bulk-related gamma-induced effects in ATLAS18 silicon sensors and their thermal evolution.
This work investigates the feasibility of neural-network-based material identification based on photon-counting computed tomography (PCCT) data. The input data were spectral vectors extracted from regions of interest (ROIs) in reconstructed tomographic slices of a phantom containing La-, Nd-, and Gd-based samples, as well as air, water, bone, and polymethyl methacrylate (PMMA). The original tomographic slices were acquired at 12 detector threshold settings (THL = 45, 55, 65, 75, 85, 95, 105, 115, 125, 135, 145, 165). For model training, the spectra were interpolated onto a uniform grid from THL 45 to THL 165 with a step of one THL unit. Large ROIs, small ROIs, and their combined dataset were considered. To avoid an overestimated performance caused by correlated ROIs extracted from the same tomographic slice, the data were split into training, validation, and test subsets at the slice level.
Silicon detectors are commonly used for spectroscopy of low-energy particles. For electrons in the 1 MeV range, a rather large thickness of 2mm is required to entirely stop the electrons and commercial options are scarce. With the instrument PERC at the FRM II, we aim to measure beta spectra from polarised and unpolarised neutrons in order to determine the axial-vector coupling constant, the element $V_\textrm{ud}$ of the Cabibbo-Kobayashi-Maskawa quark-mixing matrix, and to search for hypothetical scalar and tensor contributions. We present the characterisation of a commercially available, pixelated detector to assess its suitability to measure the entire electron energy spectrum of free neutron beta decay.
Strained membrane resonators have emerged as a promising platform for optomechanical accelerometry; however, the desired combination of low frequency and high $Q$-mass product requires a rethinking of their dissipation dilution engineering. Applying Bayesian optimization to a Si$_3$N$_4$ membrane, we discover a class of sail-like trampoline resonators in which the frequency is decreased by an order of magnitude while preserving the $Q$-mass product. We demonstrate centimeter-scale sails with kHz frequencies, $Q\sim10^7$ and $Q\times\text{mass}\sim$ 10 g. Vertically integrating a 7 kHz device with a nanoribbon, we realize a monolithic cavity optomechanical accelerometer with a room temperature thermal noise of $40\;\text{n}g_0/\sqrt{\text{Hz}}$, sufficient to resolve $μg_0/\sqrt{\text{Hz}}$ ambient vibration over a bandwidth of 4 kHz with a displacement imprecision of $10^{-14}\;\text{m}/\sqrt{\text{Hz}}$. Cryogenic arrays of sail membranes may be attractive for new physics searches and distributed quantum sensing experiments.
The task of imaging complex dust environments such as the inner astronomical units of a planet-forming disks requires dedicated mid-infrared (MIR) interferometric facilities with kilometric baselines and a large number of telescopes. Extrapolating technologies from current facilities is not straightforward. We aim to demonstrate the feasibility of using MIR heterodyne interferometry with a photonic correlation approach to recombine MIR signals from distant telescopes. We want to determine the current technological limits of such systems are. We developed a laboratory demonstration bench that can correlate MIR signals at 10 um with a photonic correlator. The photonic correlator uses commercially available telecom components at 1.5 um to transport and correlate heterodyne signals that could go up to 10 GHz in bandwidth, directly extendable to 40 GHz. We used the demonstration bench to study the noise levels and detection limits of a heterodyne interferometer with a photonic correlation. We confirm the correlation exhibited by wideband MIR signals with the photonic correlator, along with a characterization of the performance of the system and analyzed the noise levels. We show that the photonic correlator does not limit the detection and that it can be used to compensate for free-space delays at 10 um with a fiber delay at 1.5 um. With our current sub-optimal commercial infrared (IR) detectors, we have derived a detection limit of 130 Jy that is coherent flux for 8 m class telescopes with 1 h of incoherent integration. We discuss the possibility of lowering the detection limit down to typical T-Tauri stars (approximately 1 Jy) using new detectors and coherent integration based upon local oscillator synchronization with telecom fiber links.