2026-02-06 | | Total: 4
Inspired by the dilution refrigerator and magnet monitoring system developed for HAYSTAC at Yale University, Speller Lab at Johns Hopkins University developed the Fridge Real Time Monitoring System (FRTMS). The FRTMS accesses logs saved locally by the dilution refrigerator, saves these logs to various backup locations, edits the logs into a format for upload to a MySQL database, and allows the logs to be remotely monitored in near-real time.
The TRISTAN detector is an upgrade to the KATRIN experiment to enable a differential measurement of the tritium $β$-decay spectrum to search for the experimental signature of keV scale sterile neutrinos. The TRISTAN detector upgrade consists of performing precision electron spectroscopy with over 1000 silicon drift detector pixels, each responsible for recording event rates of $10^5$ counts per second. A project specific data acquisition (DAQ) system is developed to meet the experimental challenges with a remote analog to digital conversion (RADC) design. In this work, the conceptual design of the RADC DAQ is presented along with the built system for operating the TRISTAN detector upgrade. The system includes flexible signal processing logic and data management that is optimized for the high-rate precision measurement. The non-linearity of the system's readout channels are measured and shown to be stable over time. The systematic effect of this non-linearity is propagated to the sensitivity to the sterile neutrino signature and is demonstrated to be reducible to a subdominant contribution.
The network of space based optical lattice clocks (OLCs) has been proposed to detect the stochastic gravitational wave background. We investigate the overlap reduction function (ORF) of the OLC detector network and analytically derive a transformation that leaves the ORF invariant. This transformation is applicable to configurations with two OLC detectors, each equipped with a one-way link. It can map a configuration with small separation and high noise correlation to another configuration with larger separation and reduced noise correlation. Using this transformation, we obtain a favourable OLC detector network configuration with high cross-correlation response, and compare its sensitivity to that of space-based laser interferometer gravitational wave detectors.
Nonlinear SU(1,1) quantum interferometers based on non-degenerate optical parametric down-conversion exhibit strong unbalanced group velocity dispersion (GVD). This feature is intrinsic to this type of interferometer as correlated photons of vastly different frequencies propagate through a dispersive nonlinear crystal; consequently, the dispersion arises from the source itself. The resulting GVD degrades the axial point-spread function (PSF) in optical coherence tomography (OCT) with undetected photons; and physical compensation is less straightforward, in particular for non-degenerate broadband regimes due to the limited number of suitable materials. In this contribution, we analyze dispersion in bulk nonlinear interferometry and describe its implications for OCT imaging. Aspects of hardware compensation are addressed, and a novel empirical numerical method of compensation is proposed. The approach is based on the extraction of the phase component directly from the time-domain modality (high precision linearized quantum Fourier transform infrared spectrometer) and its injection into the mid-IR spectral-domain OCT signals (central wavelength of around 3770 nm) before the Fourier transform. The proposed method is compared with an alternative numerical technique. The results demonstrate a 2.2-fold improvement in axial resolution and outperform the alternative correction method in overall imaging performance.