#1 Characterization of Spurious Charge in SENSEI Skipper-CCDs [PDF] [Copy] [Kimi] [REL]

Authors: Yikai Wu, Ansh Desai, Sho Uemura, Ana M. Botti, Brenda A. Cervantes-Vergara, Fernando Chierchie, Alex Drlica-Wagner, Rouven Essig, Juan Estrada, Erez Etzion, Guillermo Fernandez Moroni, Miqueas Gamero, Stephen E. Holland, Ian Lawson, Steffon Luoma, Nathan A. Saffold, Miguel Sofo-Haro, Javier Tiffenberg, Tomer Volansky

Skipper Charge-Coupled Devices (Skipper-CCDs) are a leading technology in the search for sub-GeV dark matter and coherent elastic neutrino-nucleus scattering. A key background for rare-event searches with these detectors arises from "spurious charge" -- single-electron events generated when charges are transferred through the active region to the serial register, and across the serial register to the readout stage. We present a characterization of spurious charge in both the active region and the serial register of SENSEI Skipper-CCDs, and show that, in a well-shielded low-background environment, the dominant contribution originates in the serial register during Skipper readout, when horizontal clocks are held at constant voltage between pixel transfers. Motivated by this finding, we develop a "tri-level" clocking scheme in which the held-low phase is raised to an intermediate voltage during readout to suppress trap-mediated charge generation. Using the SENSEI detector near the MINOS cavern, we measure a serial-register single-electron density of $(2.9 \pm 0.1) \times 10^{-5}$ electrons/pixel/image under standard SENSEI readout conditions, reduced to $(4.0 \pm 0.4) \times 10^{-6}$ electrons/pixel/image with tri-level clocking -- a factor of $\sim$7 improvement. This technique offers a promising path to lower backgrounds in current and future Skipper-CCD experiments.

Subjects: Instrumentation and Detectors , Instrumentation and Methods for Astrophysics , High Energy Physics - Experiment

Publish: 2026-05-28 17:37:11 UTC


#2 The relative interfacial thermal contraction as a possible origin of the low-energy excess in cryogenic calorimeters [PDF] [Copy] [Kimi] [REL]

Authors: Vanessa Zema, Pasquale Pavone

Low threshold cryogenic calorimeters are a key technology for the advancement of rare-event searches. However, since a few years their sensitivity reach is challenged by the presence of a rising spectrum at low energies named low-energy excess (LEE), ascribed to an unknown background. In this work, we describe the LEE as absorber events induced by the relative thermal-contraction coefficient mismatch between the absorber and the SiO$_2$ amorphous layer underneath the transition-edge sensors (TESs), present for example in the case of CRESST detectors. The relative contraction in processes with temperature changes, such as during sensor fabrication and cooldown from room temperature to the temperature of operation, can induce surface dislocation nucleation. Other interfaced materials with thermal-expansion mismatch can also generate dislocations during temperature-variation processes. We formulate a simple elastic model to bridge this solid-state effect and the LEE observations. Double-TES modules have been designed to provide surface background rejection. We highlight that the presence of the LEE in the coincident event band of double-TES modules does not exclude the explanation given in this work. Exemplary, we discuss the role of the thermal boundary resistance between absorber and sensor as explanation for the presence of the LEE in the coincident-event band. We propose detector designs to test these hypotheses and mitigate the LEE.

Subjects: Instrumentation and Detectors , High Energy Physics - Phenomenology

Publish: 2026-05-28 16:34:17 UTC


#3 Thin single-crystal perovskite detector for high-energy charged particles [PDF] [Copy] [Kimi] [REL]

Authors: Z. Chubinidze, M. Auf der Maur, F. Matteocci, I. Viola, J. Endrizzi, L. Pancheri, A. Khan, G. Papalino, G. Felici, A. De Santis, G. Tinti, M. Testa

The organometal halide perovskites (OMHP) semi-conductors have shown recently a strong potential as radiation detectors, beside the well-known success in photovoltaics and as photo-detectors. Many studies have been published on X-rays detection, and a few studies about detection of alpha, beta-particles and protons. Less literature is present for high energy charged particles. OMHP-based devices for tracking and real-time monitoring for high energy particles may offer many advantages. OMHPs can be directly grown on pixelated electronics, even on curved substrates, without the need of complex and expensive bump-bonding procedures. Moreover, OMHPs have shown self-healing features after radiation exposure, which makes them attractive for high-flux applications. In this paper we report a device based on a thin single OMHP crystal, about 150 mum thick, directly grown on a patterned substrate through dewetting technique, able to detect high-energy charged particles in a high dynamic range of incident fluxes. A dedicated electronics circuit has been developed to match the expected time characteristics of the OMHP crystals. This is the first demonstration of thin OMHP single crystals being able to detect high energy charged particles of hundreds of MeV.

Subject: Instrumentation and Detectors

Publish: 2026-05-28 11:12:17 UTC


#4 Effect of increased DCR on the detection of minimum-ionizing particles with SiPMs [PDF] [Copy] [Kimi] [REL]

Authors: Katjana Neumann, Massimiliano Antonello, Lukas Brinkmann, Erika Garutti, Jörn Schwandt

Radiation damage to a Silicon Photomultiplier (SiPM), as it occurs during the lifetime of the planned CMS high-granularity calorimeter detector, increases the dark current and degrades the signal-to-noise separation for minimum-ionizing particles (MIPs) and their detection efficiency. To investigate these effects, a plastic scintillator tile air-coupled to a SiPM is used to detect MIPs from a 90Sr source, in a single-channel design similar to the tiles of the CMS high-granularity calorimeter upgrade. We compared the SiPM responses after actual radiation exposure with responses simulated in the laboratory by increasing the dark-count rate (DCR) through optical illumination with an LED light source. This optical method induces no structural damage or deep defects, thus isolating the effect of increased dark-count rate. Our results show that both radiation-induced damage and LED-induced dark-count rate increases lead to similar reductions in the MIP signal and the signal-to-noise ratio. This indicates that the primary factor for the performance degradation is the elevated dark-count rate itself, rather than additional defects in the silicon. The results demonstrate that the key effects of radiation damage on SiPMs can be effectively replicated using controlled optical illumination, providing a practical and easily accessible approach for evaluating and optimizing SiPM performance under radiation-like conditions in the laboratory.

Subject: Instrumentation and Detectors

Publish: 2026-05-28 08:37:34 UTC


#5 Measurements and simulations of X-ray radiation damage effects on CNM n-type 4H-SiC MOS capacitors [PDF] [Copy] [Kimi] [REL]

Authors: Khaoula Aouadj, Alessandro Fondacci, Arianna Morozzi, Daniele Passeri, Tommaso Croci, Sebastian Alexander Onder, Daniel Radmanovac, Thomas Bergauer, Serena Mattiazzo, Francesco Moscatelli

Silicon carbide is a promising material for radiation-hard detectors due to its wide bandgap, low leakage current, high critical electric field, and high saturation velocity. A key obstacle for its use in high-radiation environments is the incomplete understanding of surface damage at the 4H-SiC/SiO$_2$ interface.In this work, we present a combined experimental and TCAD simulation study of X-ray radiation-induced surface damage on n-type 4H-SiC MOS capacitors fabricated at CNM (Centro Nacional de Microelectronica, Barcelona), irradiated up to 10 Mrad. High-frequency (100 kHz) and quasi-static capacitance-voltage (C--V) measurements are used to evaluate the evolution of fixed oxide charge density and interface trap density as a function of dose.A dose-dependent TCAD surface model is developed and validated against the full set of measurements. The optimized model reproduces the measured C--V characteristics across the entire irradiation range and provides a physically grounded baseline for simulations of n-type 4H-SiC-based detectors. It can be used as a starting point for predictive modeling of irradiated detectors.

Subject: Instrumentation and Detectors

Publish: 2026-05-28 05:22:16 UTC


#6 Nanoparticle manipulation with a carbon fiber tip in an electron microscope for $μ$-SQUID magnetometry [PDF] [Copy] [Kimi] [REL]

Authors: Umesh Chandra Thuwal, Sumanta Maity, Clemens B. Winkelmann, Hervé Courtois, Anjan Kumar Gupta

We report a carbon-fiber-tip based nanomanipulation system integrated into a scanning electron microscope for individual nanoparticle (NP) manipulation on a surface. Electrochemically etched amorphous carbon fiber tips with excellent mechanical rigidity and sub-100 nm apex radii effectively reduce the van der Waals adhesion and enable reliable positioning of about 100 nm size NPs with about 100 nm precision. This system combines a piezoelectric bimorph for vertical tip motion, a four-quadrant piezo-tube for two-dimensional fine tip control and a two-dimensional piezoelectric walker for coarse lateral translation. Using this setup, we successfully position single Fe$_3$O$_4$ magnetic NPs on micron sized superconducting quantum interference devices for optimal magnetic coupling between them and probe a NP's magnetism.

Subjects: Mesoscale and Nanoscale Physics , Instrumentation and Detectors

Publish: 2026-05-28 08:03:02 UTC


#7 Multi-Kernel TOF-PET Image Reconstruction Using ADMM [PDF] [Copy] [Kimi] [REL]

Authors: Kibo Ote, Fumio Hashimoto, Yuya Onishi, Ryosuke Ota, Maxime Toussaint, Francis Loignon-Houle

Time-of-flight positron emission tomography (TOF-PET) detectors exhibiting multiple coincidence time resolution (CTR) components, such as those induced by the mixing of Cherenkov and scintillation photons, have attracted increasing attention. However, to fully exploit the latent potential of multi-kernel TOF-PET, new iterative image reconstruction methods are required. In this study, assuming that the events are labeled with the appropriate kernels, we propose an alternating direction method of multipliers (ADMM) for multi-kernel TOF-PET reconstruction, termed TOF-decomp ADMM. As the convergence speed of the TOF-PET log-likelihood depends on the CTR, the proposed method splits the fast- and slow-CTR log-likelihood terms and optimizes them separately under a constraint. This strategy explicitly balances the contributions of fast- and slow-CTR components and enables early stopping at iterations that yield improved contrast-noise trade-offs compared with conventional methods. We validated the proposed method using brain and image quality phantom simulations, demonstrating improved contrast-noise characteristics from a more stabilized convergence. By addressing the convergence imbalance inherent to multi-kernel TOF-PET, this work establishes a framework for exploiting the timing information available in emerging detector technologies.

Subjects: Medical Physics , Instrumentation and Detectors

Publish: 2026-05-28 00:10:48 UTC