Instrumentation and Detectors

2026-05-08 | | Total: 6

#1 Analysis of Mixed Radiation Fields at the MoEDAL Experiment Based on Real-Time Data from a Timepix Detector Network [PDF] [Copy] [Kimi] [REL]

Authors: Benedikt Bergmann, Petr Burian, Josef Janeček, Claude Leroy, Petr Mánek, James Pinfold, Stanislav Pospíšil, Richard Soluk, Michal Suk

The primary objective of this work is the determination of fluences and characteristics of fast neutrons, other hadrons, and highly ionizing particles in the environment of the MoEDAL experiment at the Large Hadron Collider. These particles constitute an experimental background for the passive Nuclear Track Detectors (NTDs) used by MoEDAL to search for tracks potentially produced by Dirac magnetic monopoles, in particular by particles indistinguishable in NTD from monopoles. The study is based on data acquired by the Timepix hybrid silicon pixel detector network, which represents the first and only active detector system installed and operated as part of the MoEDAL experiment from 2013 to 2018. The Timepix detector network enables real-time measurements of mixed radiation fields, including the composition, spectral properties, and directional characteristics of individual radiation components across different regions of the MoEDAL experimental area. The paper presents detailed results of the radiation field analysis with emphasis on neutrons and highly ionizing particles, including their directional distributions. The first results demonstrating the spatial tracking capabilities of the Timepix detectors are also reported, illustrating the reconstruction of particle direction and energy-loss profiles from individual detector frames.

Subjects: Instrumentation and Detectors , High Energy Physics - Experiment , Applied Physics , Data Analysis, Statistics and Probability

Publish: 2026-05-07 09:43:35 UTC


#2 Hot-electron bolometric mixer with negative differential resistance [PDF] [Copy] [Kimi] [REL]

Authors: Chang Yoo, Akim A. Babenko, Boris S. Karasik

We demonstrate that the conversion gain of a superconducting hot-electron bolometer (HEB) mixer can be increased by biasing the device within the negative differential resistance (NDR) region of its current-voltage characteristic. Although NDR biasing has historically been avoided due to MHz-range resistive oscillations, we show that these oscillations arise from an LC resonance formed by the bias-T inductance and the effective thermal capacitance of the HEB. By applying stability criteria analogous to those developed for tunnel diodes, we redesigned the embedding circuit to suppress this resonance and achieve stable NDR operation. Direct measurements using two monochromatic 2.5-THz sources confirm the predicted gain enhancement. These results establish NDR biasing as a viable method for improving HEB mixer performance and motivate further studies of noise behavior and circuit optimization.

Subjects: Instrumentation and Detectors , Instrumentation and Methods for Astrophysics

Publish: 2026-05-06 22:19:23 UTC


#3 Active Edge Silicon Sensors Fabricated With Edge Ion Implantation and Microwave Annealing for Dopant Activation [PDF] [Copy] [Kimi] [REL]

Authors: Andrew Gentry, Julie Segal, Angela Kok, Christopher Kenney, Sally Seidel

Silicon detectors typically require an insensitive area around their periphery to accommodate guard rings, which help maintain the electric field uniformity around edge pixels and isolate the high leakage current from the physical edges of the detector. Minimization of this insensitive region is desirable for applications in high-energy physics, X-ray experiments, and medical imaging. Existing active edge technology offers a solution for reduction or total elimination of the insensitive region, via a continuation of the highly doped backside up the sidewalls of the device. However, current methods for realizing this technology are complex and expensive. We propose a new technique that simplifies the fabrication of highly doped edges using side ion implantation and microwave annealing. Tests demonstrating the feasibility of this proposed process were performed on a set of sensors, and current versus bias voltage measurements probing the edge effects were performed before and after the edge implantation and annealing. To aid in interpretation of the results, TCAD simulations of the test devices were performed. Significant improvement in the edge leakage current is observed, indicating the promise of this simplified process for fabrication of active edge sensors.

Subject: Instrumentation and Detectors

Publish: 2026-05-06 21:23:56 UTC


#4 Localized efficient in-vacuum loading of $\sim$0.1-10 $μ$m spherical and plate-like particles into optical traps using a pulled glass capillary [PDF] [Copy] [Kimi] [REL]

Authors: Alexey Grinin, Andrew Dana, Mark Nguyen, Scott Grudichak, Katarina Boskovic Guy, Shelby Klomp, Shafaq Gulzar Elahi, Sam Borden, Zhiyuan Wang, George Winstone, Andrew A. Geraci

We demonstrate a compact piezoelectric-driven micropipette launcher for localized in-vacuum delivery of nano- and microparticles into optical traps. The launcher has been integrated into multiple optical trapping setups, including a single-beam trap, a non-interfering dual beam trap, and a standing-wave dual beam trap, showcasing the versatility and ease of integration of the setup. Using the micropipette launcher, we have successfully trapped silica spheres of $170\text{ nm}$, $300\text{ nm}$, 3 $μ\text{m}$ diameter, as well as 6 $μ\text{m}\times$ 0.2 $μ\text{m}$ $β$-NaYF hexagonal prisms and $\sim 100$ nm diameter high-purity nanodiamonds. We characterize the performance of the device including the peak acceleration, angular distribution of emitted particles, and the dependence on vertical displacement between the pipette tip and optical trap. Trapping efficiency as high as 93\% is achieved.

Subjects: Optics , Instrumentation and Detectors

Publish: 2026-05-07 06:09:45 UTC


#5 Development of a Proton Therapy Research Beamline with FLASH and Minibeam Capabilities at the 18 MeV Bern Medical Cyclotron [PDF] [Copy] [Kimi] [REL]

Authors: Eva Kasanda, Lars Eggiman, Thierry Stammbach, Pierluigi Casolaro, Gaia Dellepiane, Alexander Gottstein, Jan Gruber, Isidre Mateu, Paolo Pellicioli, Maria Vittoria Rossi, Paola Scampoli, Cristian Fernandez Palomo, Saverio Braccini

Advanced radiotherapy approaches such as FLASH irradiation and spatially fractionated radiotherapy (SFRT) show potential to improve the therapeutic ratio, yet their biological mechanisms and optimal delivery parameters remain uncertain. Progress requires accessible proton research platforms with flexible temporal and spatial dose delivery. We report on the adaptation of the Beam Transfer Line (BTL) of the Bern Medical Cyclotron (BMC) for radiobiology research with FLASH and proton minibeam capabilities. The BMC is optimized for the production of radionuclides for medical imaging, and is able to extract currents up to 150 $ \mathrm{μA}$. The 18 MeV proton beam was passively shaped using collimators, scattering foils, and extended drift space to generate irradiation fields. A dosimetric framework was implemented using an in-beam ionization chamber and radiochromic film with LET-dependent corrections. Beam uniformity and SFRT profiles with various grid spacings were evaluated at realistic target distances. The developed beamline enables stable delivery under controlled conditions in both conventional and FLASH regimes, spanning dose rates from 0.01 to 100 Gy/s. Dose uniformity within a 20 mm radius was below 8\%. Film measurements confirmed the need for LET-dependent corrections and indicated that quantitative dosimetry in in-vitro setups is achievable with appropriate LET corrections. The low proton energy (15.54(12) MeV extracted into air, 8.14(28) MeV delivered to cells in flask) facilitates compact SFRT implementation with well-resolved minibeams. The adapted BMC provides a flexible and accessible platform for systematic pre-clinical proton radiobiology studies under varied dose-rate and spatial delivery conditions. This supports optimization of emerging modalities such as proton FLASH and SFRT and helps bridge accelerator technology and radiobiology.

Subjects: Medical Physics , Instrumentation and Detectors

Publish: 2026-05-06 20:57:29 UTC


#6 Orbital angular momentum transmission in time-varying scattering media using dual orthogonal polarization channels [PDF] [Copy] [Kimi] [REL]

Authors: Heshen Li, Jin Wei, Tianshun Zhang, Wen Chen

Orbital angular momentum (OAM) has been regarded as a potential dimension for optical communication and related fields. Despite several studies, the transmission of OAM beams through time-varying scattering media remains a challenge. In this paper, we report a method for OAM transmission through time-varying scattering media using dual orthogonal polarization channels, in which one channel carries a perfect vortex beam (PVB) carrying data, and the other serves as a reference plane wave. By calculating the second-order cross-correlation of speckle patterns generated by the PVB and the plane wave, the original data can be decoded. It is also shown that multiplexed PVBs carrying specific topological charges can produce interference patterns in the acquired cross-correlation images, thereby greatly enhancing transmission capacity. Experimental results show that the proposed method can transmit at least 6 bits per beam with 100% accuracy. Moreover, the proposed method is highly robust to variations in the receiving end's position in both radial and axial directions. The proposed method enables the practical deployment of OAM transmission in realistic optical communication and related applications.

Subjects: Optics , Applied Physics , Instrumentation and Detectors

Publish: 2026-04-24 13:30:09 UTC