Instrumentation and Detectors

2026-10-20 | | Total: 12

#1 Optical imaging in dual-phase xenon time projection chambers for neutrinoless double beta decay searches [PDF] [Copy] [Kimi] [REL]

Authors: Adam D. Tidball, Jingke Xu, Brian G. Lenardo, Nicholas Antipa

Dual-phase xenon time projection chambers (TPCs) are the leading technology for WIMP dark matter searches and have also demonstrated competitive sensitivities to neutrinoless double beta decays (0$νββ$) of \ce{^{136}Xe}. However, the large energy disparity between these two signals requires different detector optimizations. In particular, 0$νββ$\ searches in liquid xenon desire efficient rejection of closely located multiscatters of background gamma rays near the 0$νββ$\ energy, a capability achieved only in the vertical dimension in existing dual-phase xenon TPCs. We propose a highly customized, wide-angle optical system that can be conveniently integrated into large xenon TPCs and provide mm-scale transverse position resolution for MeV signals by imaging gas electroluminescence light. This approach preserves a TPC's low-energy sensitivity and optimizes a single experiment for both dark matter and 0$νββ$\ searches. This paper discusses the design, simulated performance, and implications of the imaging system for future liquid xenon-based 0$νββ$\ searches.

Subjects: Instrumentation and Detectors , High Energy Physics - Experiment

Publish: 2026-10-19 17:04:48 UTC


#2 Characterization of the R14374-10 photomultiplier tube for the Pacific Ocean Neutrino Experiment [PDF] [Copy] [Kimi] [REL]

Authors: O. Aghaei, M. Agostini, A. Alexander Wight, K. Baş, N. Baily, P. S. Barbeau, A. J. Baron, S. Bash, C. Bellenghi, M. Boehmer, M. Brandenburg, Z. Brisson-Tsavoussis, D. Brussow, P. Bunton, N. Cedarblade-Jones, K. Clark, B. Crudele, M. Danninger, T. DeYoung, M. Dinkel, N. Exconde, A. Gärtner, J. Garriz, D. Ghuman, L. Ginzkey, V. Gousy-Leblanc, D. Grant, A. Grimes, C. Haack, R. Halliday, M. Heesemann, D. Hembroff, F. Henningsen, M. Herle, O. Janik, V. Jourdenais, W. Kang, S. Karanth, T. Kerscher, S. Kerschtien, S. Koch, K. Kopański, C. Kopper, P. Krause, C. B. Krauss, N. Kurahashi, C. Lagunas Gualda, A. Lam, T. Lavallee, K. Leismüller, R. Li, S. Loipolder, C. Magee, S. Magel, P. Malecki, T. Martin, A. Maunder, C. Miller, N. Molberg, R. Moore, B. Nührenbörger, B. Nichol, W. Noga, B. Owens, R. Ørsøe, L. Papp, N. Park, V. Parrish, P. Pfahler, J. Pflanz, B. Pirenne, E. Price, A. Rahlin, M. Rangen, E. Resconi, N. Retza, S. Robertson, M. F. Rodriguez-Pilco, A. Šaina, D. Salazar-Gallegos, A. Scholz, L. Schumacher, P. Senyk, S. Sharma, S. Shively, C. Spannfellner, J. Stacho, I. Taboada, K. Tchiorniy, J. Thwaites, J. P. Twagirayezu, M. Un Nisa, B. Veenstra, M. Velazquez, L. von der Werth, C. Weaver, N. Whitehorn, B. Winnicky-Lewis, L. Winter, R. Wroński, J. P. Yañez, S. Yun-Cárcamo, A. Zaalishvili et al. (73 additional authors not shown)

The Pacific Ocean Neutrino Experiment (P-ONE) is a planned cubic-kilometer-scale neutrino telescope that will be deployed in the Pacific Ocean, leveraging deep-sea infrastructure operated by Ocean Networks Canada (ONC). The first detector line will deploy 320 3-inch Hamamatsu R14374-10 photomultiplier tubes (PMTs) to detect Cherenkov light produced by charged particles propagating through water, as well as light from calibration sources and optical backgrounds. This article presents the systematic characterization of all PMTs to be integrated into the first detector line prior to deployment, ensuring compliance with all detector acceptance criteria. All PMTs satisfy the specified performance criteria: the average transit-time spread (TTS) was measured to be $1.73\pm 0.15\,$ns, and the average charge resolution at a gain of \num{5e6} was $0.43\pm 0.03\,$pC; the average after-pulse rate was measured to be around 6$\,\%$. The integrated P-ONE data acquisition (DAQ) system was also tested and cross-validated against a laboratory digitization system. The second part of the paper presents an in-depth characterization of a subset of six PMTs, focusing on the key properties required for detector simulations, including linearity, after-pulse rate, quantum efficiency, and relative collection efficiency. PMT linearity was measured at a gain of \num{5e6} using the complete P-ONE readout electronics, and the response was found to remain linear for signals up to 150 photoelectrons. After-pulse contributions from $\text{Cs}^{+}$, $\text{He}^{+}$, and other ions were identified in the subset. The peak quantum efficiency was measured to be $27.0\pm0.7\,\%$ at 395\,nm. Using measurements of the relative detection efficiency, the collection efficiency was found to differ by a wavelength-independent offset of 10--15$\%$ across the measured wavelength range.

Subjects: Instrumentation and Detectors , High Energy Physics - Experiment

Publish: 2026-10-19 12:48:53 UTC


#3 Demonstration of continuous non-invasive monitoring of plant metabolism using mid-infrared photoacoustic spectroscopy [PDF] [Copy] [Kimi] [REL]

Authors: Ellyne Liégeois, Héloïse Hannart, Jules Skubich, Maeva Doron, Kevin Jourde, Johan Decelle, Yann Bresson, Sylvain Delzon, Régis Burlett

Life is a rhythmic process driven by cellular and physiological mechanisms that allow plants to respond and adapt to their environment. In addition to natural fluctuations, plants are increasingly exposed to environmental stresses, mainly caused by climate change and anthropogenic pollution. Multiple approaches across different biological scales (gene, cell, metabolite, and physiology) have shed light on acclimation mechanisms but generally lack sufficient temporal resolution. Establishing a non-invasive and high-temporal-resolution monitoring method to measure plant activity across different conditions is therefore needed to fully assess how plant metabolism changes under stress. Here, we established a novel approach to perform continuous and non-invasive mid-infrared photoacoustic spectroscopy on vascular plants, with the aim of identifying and monitoring the chemical composition of peripheral tissues, including sap, over periods ranging from a few minutes to several months. We describe an experimental setup, the physics underlying its operation, and present a multi-day acquisition. Compared with controls, data enabled to identify a diurnal pattern, with peaks of approximately equal duration, that recurred consistently over the experiment. Estimations of the impact of instrumental and environmental fluctuations indicate that the signal amplitude and trends cannot be explained by instrumental drifts. The experiment thus demonstrated the detection of a signal associated with plant physiological activity. While its origins remain to be clarified, this preliminary experiment demonstrates the feasibility of the measurements and provides a basis for future developments.

Subjects: Instrumentation and Detectors , Biological Physics , Optics

Publish: 2026-10-19 11:03:19 UTC


#4 The RUBIK satellite payload concept: a 3D-segmented plastic scintillation-based particle tracking detector [PDF] [Copy] [Kimi] [REL]

Authors: Roman Bergert, Dzmitry Kazlou, Hartmut Schotte, Niclas Fiedler, Hans-Georg Zaunick, Kilian-Simon Baumann, Kai-Thomas Brinkmann

We present the design concept and first experimental results of RUBIK, a three-dimensional resolving plastic scintillation detector developed as a scientific payload for the Research and Observation in Medium Earth Orbit satellite mission of the Institute of Space Systems of the University of Stuttgart. The name RUBIK is inspired by the Rubik's Cube, a familiar example of a three-dimensional segmented structure, reflecting the 5x5x5 modular arrangement of the sensitive volume. The sensitive volume consists of 125 PVT-based plastic scintillator unit cubes, each penetrated by two perpendicularly aligned wavelength-shifting fibres, which guide scintillation photons to silicon photomultipliers (SiPMs), providing 50 independent readout channels. Custom readout electronics, comprising two discriminator boards with per-channel programmable thresholds, an FPGA-based data-acquisition board, and a dedicated power and bias distribution board, have been developed exclusively from commercial off-the-shelf components. A single-layer prototype with ten readout channels was used for concept validation through SiPM bias voltage and temperature characterisation, and a time-over-threshold based amplitude reconstruction method was validated against radioactive source and cosmic ray measurements. First hit-pattern measurements with 220 MeV protons at a clinical proton therapy facility confirmed that spatially resolved hit clusters consistent with the expected beam geometry were observable in the single-layer readout, demonstrating the capability to resolve particle-induced signal patterns as a first step towards 3D track reconstruction in the full instrument.

Subject: Instrumentation and Detectors

Publish: 2026-10-19 10:48:22 UTC


#5 Phonon-dominated thermal conductivity of a superconducting amorphous MoSi thin film [PDF] [Copy] [Kimi] [REL]

Authors: Jacopo Piantanida Chiesa, Tom Q. Post, Martin P. van Exter, Michiel J. A. de Dood

We use the differential 3ω method to directly measure the temperature dependent thermal conductivity for about 90 nm Mo0.78Si0.22 thin films. The measurements are performed in a closed-cycle cryostat to access the temperature range between 50 K and 300 K. The MoSi thin films are capped with Al2O3 and probed with a Pt wire. The results show that the thermal conductivity does not satisfy the Wiedemann-Franz law. This implies that thermal transport in MoSi is not dominated by electrons but by phonon-like excitations, contrary to what is assumed in many electro-thermal models of superconducting devices. We argue that this property might be related to the weak localization visible in the resistivity as a function of temperature curves of the superconductor.

Subjects: Instrumentation and Detectors , Materials Science , Superconductivity

Publish: 2026-10-19 10:24:08 UTC


#6 Development of microwave multiplexed readout for athermal phonon TES-based detectors [PDF] [Copy] [Kimi] [REL]

Authors: Tran Tsan, Douglas A. Bennett, Daniel T. Becker, Rebecca Carney, Johnathon D. Gard, John A. B. Mates, Joel N. Ullom, Michael R. Williams, John C. Groh

Continued advancements in sub-eV calorimetric measurements are being enabled through the athermal phonon detection channel, with applications spanning a diverse array of fields, including low-mass dark matter searches, coherent elastic neutrino-nucleus scattering, and quantum information science. While Transition Edge Sensors (TESs) have achieved the lowest thresholds to date, they face significant scalability bottlenecks due to the inherent constraints of conventional SQUID readout architectures. To address this limitation, we present an update on R&D to develop practical, highly multiplexed, microwave readout for athermal phonon TESs, which can enable a dramatic increase in both sensor count and target mass, with a focus on sub-GeV dark matter searches as a target application. This work leverages advances from highly scaled mm-wave, x-ray, and gamma-ray TES systems, adapting them to the unique needs of low-threshold rare event measurements. We quantify the basic readout functionality and noise level in our dilution refrigerator testbed and demonstrate operation of a variety of TES devices with saturation powers significantly lower than mm-wave and x-ray devices. We demonstrate proof-of-concept multiplexed readout of background event pulses, bound the readout's contribution to the parasitic TES background load to <1 fW, and discuss a cryogenic inline RF filtering scheme. These results demonstrate practical solutions to several of the key challenges that must be solved before a next-generation athermal phonon detector at scale is realized.

Subjects: Instrumentation and Detectors , Superconductivity , High Energy Physics - Experiment

Publish: 2026-10-16 22:52:27 UTC


#7 Time-over-threshold versus pulse-height energy reconstruction in a PbWO$_4$ calorimeter read out by SiPMs [PDF] [Copy] [Kimi] [REL]

Authors: Stefano Carsi, Erik Vallazza

The time over threshold (ToT) can be measured with a comparator and a time-to-digital converter, avoiding the waveform digitizers normally used to read out calorimeter prototypes. We assess how much the energy resolution degrades when the pulse height (PH) is replaced by the ToT, using data collected in June 2024 at the CERN PS T9 beam line with 2-6 GeV electrons on OREO, a calorimeter of two $3\times3$ matrices of PbWO$_4$ crystals read out by SiPMs and sampled at 500 MS/s, and 1-6 GeV electrons on a lead-glass calorimeter sampled at 100 MS/s. The ToT is emulated offline on the recorded waveforms and converted into an amplitude, so that the same reconstruction chain is applied to both estimators. For OREO in random orientation the PH gives $σ/μ$ = 3.6% at 2 GeV and 2.4% at 6 GeV. A single-threshold ToT worsens the resolution by 50-80%, because one threshold cannot cover the dynamic range, while a dual-threshold ToT gives 3.9% and 2.6%, i.e. 6-10% worse than the PH. Extending the waveforms beyond the 1 $μ$s acquisition window shows that the window is not the limiting factor, and an emulated shaper that reduces the decay time to 50-100 ns preserves the result with a ToT of 0.3-0.5 $μ$s instead of 1.2 $μ$s. The ToT-to-amplitude conversion can also be calibrated with a scan of the two thresholds, without any digitizer, with a resolution comparable to the one obtained with PH-based curves. For the lead glass, whose pulses are less than two samples wide at half maximum, the ToT cannot be emulated reliably. We also find that a previous analysis of the same data is consistent with a drift normalization that does not subtract the pedestals; subtracting them improves the resolution by up to 1.6 percentage points.

Subject: Instrumentation and Detectors

Publish: 2026-10-16 20:08:15 UTC


#8 Correlated detection of electrons and ions emitted from laser-induced nanoplasmas in doped helium nanodroplets in the single-shot single-cluster regime [PDF] [Copy] [Kimi] [REL]

Authors: Keshav Sishodia, Cristian Medina, Robert Moshammer, Thomas Pfeifer, Andreas Heidenreich, Marcel Mudrich, Sivarama Krishnan

We present single-cluster single-shot correlated measurements of electron velocity-map images and ion time-of-flight traces from individual laser-induced nanoplasmas in xenon-doped helium nanodroplets. Simultaneous detection associates the ion composition, ion kinetic energies, and electron energies with the same nanoplasma event. The detected ion composition separates events into populations dominated by He+ mono-cations versus those dominated by He^{2+} di-cations, with markedly different ion energies and electron kinetic energies. The He+-dominated population correlates well with low electron kinetic energies (< 0.5 eV), whereas the distribution of maximum electron kinetic energies for the He^{2+}-dominated population shows a peak around 1 eV. Molecular dynamics simulations averaged over the focal volume suggest that local laser intensity contributes to this separation. These correlations provide single-event observables for classifying nanoplasmas and will support real-time shot-to-shot sorting in single-particle coherent diffractive imaging experiments.

Subjects: Atomic and Molecular Clusters , Atomic Physics , Instrumentation and Detectors , Plasma Physics

Publish: 2026-10-19 12:33:35 UTC


#9 A 4-20 GHz Superconducting 90deg Hybrid Using Capacitively Loaded Coupled Lines for 2SB Heterodyne Receivers [PDF] [Copy] [Kimi] [REL]

Authors: François Joint, Max Behrens, Denis Meledin, Cristian Lopez, Magnus Strandberg, Sven-Erik Ferm, Mathias Fredrixon, Leif Helldner, Alexei Pavolotsky, Erik Sundin, Igor Lapkin, Victor Belitsky, Vincent Desmaris

We report the design and cryogenic characterisation of a broadband superconducting 90deg intermediate-frequency (IF) hybrid covering 4 to 20 GHz for sideband-separating (2SB) heterodyne receivers. The hybrid is implemented in thin-film niobium using capacitively loaded edge coupled transmission lines, avoiding the air-bridge interconnections required in Lange-coupler layouts while retaining a compact superconducting implementation with low loss and good quadrature balance. Cryogenic measurements using Vector Network Analyser (VNA) show amplitude and phase imbalance better than 0.6 dB and 6deg, respectively, across the full band. When used in a 2SB receiver, this level of IF balance is consistent with the observed image-rejection performance in the 10-20 dB range, for the full receiver. The design supports the development of wide-instantaneous-bandwidth 2SB receivers for millimeter and submillimeter observatories, improving spectral grasp for broadband line surveys and high-redshift line searches.

Subjects: Instrumentation and Methods for Astrophysics , Instrumentation and Detectors

Publish: 2026-10-17 20:25:59 UTC


#10 PRIMA prototype spaceflight KID readout electronics laboratory characterization [PDF] [Copy] [Kimi] [REL]

Authors: Adrian K. Sinclair, Chris Albert, C. Matt Bradford, Patrick Brown, Sean Bryan, Jesse Coldsmith, Jennifer Corekin, Sumit Dahal, Thomas K. Devlin, Thomas Essinger-Hileman, Logan Foote, Marc Foote, Draisy Friedman, Alessandro Geist, Jason Glenn, Christopher Green, Kyle Helson, Kevin Horgan, Tracee Jamison-Hooks, Elijah Kane, Jared Lucey, Philip Mauskopf, Lynn Miles, Sanetra Bailey Newman, Gerard Quilligan, Cody Roberson, Salman Sheikh, Manuel Vega, Eric Weeks, Christopher Wilson, Travis Wise

We present further development and testing of prototype kinetic inductance detector (KID) readout electronics for the PRobe far-Infrared Mission for Astrophysics (PRIMA). PRIMA is a NASA Probe-class astrophysics mission concept with two science instruments, FIRESS and PRIMAger, which provide spectroscopic and polarimetric imaging from 24 to 261 um. Together these instruments will explore the far-infrared sky with spatial-spectral mapping speeds that exceed previous studies by orders of magnitude, opening a vast discovery space. This increase in mapping speed is achieved by densely packed ultra-sensitive KIDs and cryogenically cooled optics. The PRIMA flight readout electronics will use the build-to-print SpaceCube Mini v3.0 which houses a radiation-tolerant Kintex KU060 field programmable gate array (FPGA). A custom high-speed digitizer board is being designed along with an RF electronics (RFE) board. The RFE was designed to provide programmable gain, band filtering, and RF switching between instruments. The prototype readout electronics, including the RFE, use functionally equivalent parts to the flight parts. In this proceeding we measure the readout loopback noise performance in the second Nyquist zone and timestream cross-talk performance. We present preliminary sweeps with the prototype readout coupled to prototype FIRESS detectors. Lastly, we demonstrate a cosmic ray pulse detection and real-time removal with an algorithm implemented in firmware.

Subjects: Instrumentation and Methods for Astrophysics , Instrumentation and Detectors

Publish: 2026-10-17 00:09:24 UTC


#11 Missing Light, Misleading Confidence: Optical-Module Readout Loss and Signal Reliability in Neutrino Telescopes [PDF] [Copy] [Kimi] [REL]

Authors: Thammarat Yawisit, Pittaya Pannil

Optical neutrino telescopes reduce the photomultiplier signals of an optical module or string segment to compact multichannel summaries, and readout loss can make these summaries unreliable. We asked whether availability-based quality gates, which accept a summary when enough of the readout was live, can certify a summary of inter-channel statistical consistency (called coherence here; not optical coherence) under readout loss, and where they fail. We used public IceCube pulses (9,484 string records) and the released hits of KM3NeT event KM3-230213A with controlled readout loss, together with a replay of real KM3NeT readout flags. In a two-by-two design we compared a published recursive support state with direct mask support, and calibrated every threshold on development records. The support state is a function of the mask and added no information. On IceCube the support-gated rule retained 0.16 percentage points more usable summaries, an effect of the window at which support was read that reversed sign at a looser tolerance; on KM3NeT it accepted nothing. The gates accepted only records with nearly intact masks, including records whose charge had been depleted by signal-dependent loss that the mask does not record. Pulse loss during live acquisition and timing jitter passed every availability gate, which then accepted summaries of which up to 66% were unreliable. Availability flags are therefore necessary but not sufficient, and signal-based checks are needed. This work uses public data and is not an IceCube or KM3NeT Collaboration result.

Subjects: Instrumentation and Methods for Astrophysics , Instrumentation and Detectors

Publish: 2026-10-15 16:58:51 UTC


#12 Junction Geometry Survives an Unidentifiable Blur [PDF] [Copy] [Kimi] [REL]

Authors: Sohail, Sarkar, Shakuntala Baichoo

Thin filaments cross in microscopy, and dispersed spectra cross on X-ray detectors. At a junction, where these structures cross or branch, how many straight arms meet, and which way do they go? Unknown blur obscures the answer. At a balanced crossing, distinct Gaussian blurs can even produce the same observation law. We show that the arms can still be recovered. For separated rays of nonvanishing weight and an unknown centered Gaussian-mixture blur, a distance combining arm count, directions, relative weights and supporting lines is bounded by a constant times the Euclidean difference in cell probabilities on a sufficiently fine fixed grid. The bound is uniform over a bounded model class, including unidentifiable blurs. From $n$ positions or photon counts, the minimax error is of order $n^{-1/2}$. This rate is proved for a global estimator. In practice we fit rays and blur by constrained local likelihood, reducing the BIC count when two detectors agree on fewer arms in the microscopy studies. Across three studies with protocols fixed before evaluation, on 360 crossings and branches assembled from measured single-molecule localizations, the fit gets the arm count and every direction within $10^\circ$ 24 to 37 percentage points more often than a tuned fixed-scale Hessian ridge detector, averaged over 25 to 400 localizations. On acute angles with correct counts, mean absolute error is $3.5^\circ$ to $4.3^\circ$, versus $10.4^\circ$ to $15.5^\circ$. On Chandra spectra, 38 of 90 fits at 800 photons find all four arms within $10^\circ$; among these, median error is $0.023^\circ$.

Subjects: Computer Vision and Pattern Recognition , Instrumentation and Detectors

Publish: 2026-09-30 16:58:55 UTC