Total: 1
We propose and evaluate a source-as-detector search for the de-excitation of the long-lived isomer $^{180\mathrm{m}}\mathrm{Ta}$ in natural tantalum (Ta), using a $γ$-ray transition-edge-sensor (TES) array. We exploit two capabilities not available in conventional high-purity germanium (HPGe) searches: (i) near-unity containment of low-energy secondaries (internal-conversion electrons and characteristic X rays), as well as the nuclear recoil, enabling a calorimetric, event-by-event measurement of the total energy deposited in the absorber; and (ii) a delayed-coincidence tag based on the subsequent ${}^{180}$Ta electron-capture (EC) decay to ${}^{180}$Hf. We evaluate the $3σ$ discovery reach for internal conversion (IC) and for dark-matter-induced de-excitation in two benchmark scenarios: a strongly interacting dark-matter (DM) subcomponent and inelastic DM with off-diagonal couplings. Using a background model based on intrinsic radioactivity in the Ta absorber and realistic detector performance, we show that arrays with $N_{\mathrm{TES}}=256$ and $1{,}000$ pixels can reach the theoretically expected IC half-life within $2.6$~yr and $0.66$~yr, respectively. For an array with $N_{\mathrm{TES}}=10^4$ and a five-year exposure, the projected sensitivity to DM-induced de-excitation surpasses limits inferred from HPGe non-observations of ${}^{180\mathrm{m}}$Ta and probes regions of parameter space not covered by current direct-detection experiments.